Knowledge
Home > News > Content
Operation Procedure Standard Of Box Gluing Machine
The general operation procedure standard of box gluing machine includes three aspects: power supply, maintenance and production.Here are some brief introductions of operation procedure standard of box gluing machine.
1.Operation procedure standard of box gluing machine about power supply.
(1) Turn on the power.
(2) Check the power indicator light to see if it is normally energized. (3) Check whether the air compressor is running in the direction of inflation.
(4) Jog the machine and observe whether it is operating normally. (Listen, watch)
2.Operation procedure standard of box gluing machine about maintenance.
(1) Clean the box gluing machine (go to and from get off work every day)
(2) The parts that need to be oiled for box gluing machine maintenance should be oiled once or twice a week. The parts that need to be buttered should be added once every half a month.
(3) Air compressor maintenance, observe whether there is oil in the air compressor, and drain the water once or twice a week.
(4) As to maintenance of the box gluing machine, after each production, the machine should be cleaned up. The rubber kettle should be cleaned once . The box gluing machine should be maintained once a month.
3.Operation procedure standard of box gluing machine about production.
(1) Carefully read the work order, determine the process requirements, and compare the work packaging according to the process requirements. Polished products are produced with polished glue or white latex water. Smooth glue, dumb glue products generally use yellow glue, and UV products must be polished first and then glued with UV glue.
(2) When comparing the boards, compare the boards according to the size of the box. According to the adhesive position of the box, determine the size and position of the glue.
(3) After the completion of the comparison board, first produce 10-20 pieces to know whether there are sticking flowers, easy glue, internal glue, false glue, supporting flowers, high and low thread, cover thread, bell mouth and other common problems.
(4) Check the sample and sign the first part. After confirming the correctness, it can be producted.